Results for Volatile Organic Compounds (VOCs)

You may use, distribute or copy the information in these data tables, with attribution to Biomonitoring California.
For more information, visit our researchers page or contact us.
Results on page last updated:

Chemical Group: Volatile Organic Compounds (VOCs)

  • Measured in: Urine

Project: Stockton Air Pollution Exposure Project (SAPEP)

Unweighted Results

Chemical measured Indicates Exposure to Adjusted for Units Number of people tested Number of Samples Geometric mean 95% Confidence Interval Selected Percentiles Detection Frequency Reporting limit, wet weight Notes
Lower Upper 25th 50th 75th 90th
1-MHBMA and 2-MHBMA 1,3-Butadiene NA µg/L 18 69 * * * <LOQ <LOQ <LOQ <LOQ 1.4% 0.5 µg/L ‡
1-MHBMA and 2-MHBMA 1,3-Butadiene Creatinine µg/g creatinine 18 69 * * * <LOQ <LOQ <LOQ <LOQ 1.4% 0.5 µg/L ‡
2-HPMA Propylene oxide NA µg/L 18 69 41.0 26.0 64.7 28.3 43.1 71.9 133 100% 1.0 µg/L ‡
2-HPMA Propylene oxide Creatinine µg/g creatinine 18 69 36.7 26.3 51.3 22.2 31.1 50.5 120 100% 1.0 µg/L ‡
3-HPMA Acrolein NA µg/L 18 69 374 270 518 314 420 587 932 100% 1.0 µg/L ‡
3-HPMA Acrolein Creatinine µg/g creatinine 18 69 331 274 398 223 309 444 728 100% 1.0 µg/L ‡
CNEMA Acrylonitrile NA µg/L 18 69 1.66 1.06 2.60 1.38 2.45 3.28 6.07 88.4% 0.5 µg/L ‡
CNEMA Acrylonitrile Creatinine µg/g creatinine 18 69 1.46 1.01 2.10 1.03 1.75 2.51 3.73 88.4% 0.5 µg/L ‡
HPMMA Crotonaldehyde NA µg/L 18 69 233 152 358 168 239 417 865 100% 1.0 µg/L ‡
HPMMA Crotonaldehyde Creatinine µg/g creatinine 18 69 210 167 264 138 200 276 546 100% 1.0 µg/L ‡
PMA Benzene NA µg/L 18 69 * * * <LOQ <LOQ 0.180 0.360 40.6% 0.1 µg/L ‡
PMA Benzene Creatinine µg/g creatinine 18 69 * * * <LOQ <LOQ 0.182 0.369 40.6% 0.1 µg/L ‡
Footnotes
  • *Geometric mean was not calculated because the chemical was found in less than 65% of the study group
  • ‡SAPEP collected multiple urine samples from study participants. The geometric means were estimated using random effects models to account for multiple samples per participant. Percentiles and detection frequencies were based on the total number of samples collected.